Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8754840

- Product Categories
- Friendly Links
- home > Supply > Xiamen circulating water treatment / Zhangzhou Circulating Water Treatment / Quanzhou circulating water treatment Xiamen Australia Springs
Xiamen circulating water treatment / Zhangzhou Circulating Water Treatment / Quanzhou circulating water treatment Xiamen Australia Springs
Information Name: | Xiamen circulating water treatment / Zhangzhou Circulating Water Treatment / Quanzhou circulating water treatment Xiamen Australia Springs |
Published: | 2012-02-26 |
Validity: | 90 |
Specifications: | Standard |
Quantity: | 100.00 |
Price Description: | |
Detailed Product Description: | Xiamen, Quanzhou, Zhangzhou, industrial water treatment equipment / Fujian, Xiamen, Quanzhou, Zhangzhou, industrial water treatment / Fujian, Xiamen, Quanzhou, Zhangzhou industrial cycle friendly reminder! ! ! Australia Springs brand of Fujian, Xiamen, Quanzhou, Zhangzhou, industrial circulating water treatment equipment, the best quality! Our production of industrial water treatment equipment in Australia Springs brand by the customer favorite Xiamen, Quanzhou, Fujian, Xiamen, Fujian, Quanzhou, Zhangzhou Zhangzhou industrial water treatment equipment applying its unique system installations and quality service come out on top in the market of Fujian. I am Secretary of industrial water treatment equipment in Xiamen, Quanzhou, Zhangzhou, Fujian and other parts have a very successful case, the following detailed description. . Fujian, Xiamen, Quanzhou, Zhangzhou, industrial circulating water treatment equipment systems Overview Overview of issues facing the daily operation of the circulating cooling water system: 2.1 equipment fouling, impede heat transfer, increasing energy consumption, reduce the scaling of production load: means the dissolved or suspension of the inorganic, for various reasons, and deposited on the metal surface. Cooling water is rich in bicarbonate, calcium unstable salts, heat, the heat transfer tube wall into the dense hard scale of calcium carbonate and other rules deposited in the wall, the heat transfer efficiency is only about 1% of the carbon steel, that is, heat transfer tube wall deposition 0.5mm thick hard scale, which is equivalent to the heat exchange tube wall thickness of 50mm, a serious impediment to heat transfer in the normal increase in energy consumption, and thus pose a great impact on the production load, and even parking. 2.2 a breed of slime debris and impede heat transfer; accelerate equipment corrosion, especially pitting accidents impede heat transfer: the mucus of microbial metabolism (the same as the glue has a strong adhesive), suspended solids and the water cycle (add water into the cooling tower exhaust cooling water washing and air dust to enter) and microbial carcasses intertwined adhesion with the adhesion with the flow in the device wall, soon to form the scale of a layer of creamy layer, namely the so-called surface of porous soft scale. Debris attached to the heat exchange tube wall, is a poor conductor of heat (thermal conductivity is very small, only one percent of the stainless steel), thus giving the effect of heat transfer decreased significantly affect the production load. Pitting: soft dirt layer porous form a good channel for the infiltration of oxygen in the circulating water conductivity in the pool (rich in salt), the formation of numerous small concentration cell, each small battery is a point of power chemical reaction, thus speeding up the equipment pitting the occurrence of a long time that the depth of corrosion perforation accidents. 2.3 The equipment corrosion and shorten the life of corrosion: metal consumption of damage by chemical or electrochemical reaction. Main in the circulating water system, mainly in the dissolved oxygen in a chemical or electrochemical corrosion, this corrosion will cause the water-cooled equipment damage or life reduction, but also caused due to corrosion caused by water coolers perforation, causing leakage of the process medium unplanned stop accidents, the other due to corrosion of stainless lutetium, will cause the decline in efficiency of heat transfer, or pipeline blockage hazards. Circulating cooling water treatment technical requirements of 3.1 circulating cooling water system design standards hg / t 20690-2000 circulating cooling water treatment design and the technical requirements of the chemical companies, "gb50050 95" 3.2 supplementary water pretreatment water quality requirements of 3.3 Circulating Water System treatment effect indicators, |
Admin>>>
You are the 13085 visitor
Copyright © GuangDong ICP No. 10089450, The Xiamen Australia Spring Environmental Protection Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 13085 visitor
Copyright © GuangDong ICP No. 10089450, The Xiamen Australia Spring Environmental Protection Technology Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility